In the EVB71120 data sheet in the fig. 6 the selection of 10,7 MHz IF is made by a connection of IFSEL to GND. Is it correct?


dru_Melexis

Posted 9 May at 2:07PM  Edit      Reject because  

Melexis  Moderator

Joined: 1 February 2006
Location: CH
Posts: 90

Back to Top

Dear,

For an intermediate frequency IF2 of 10.7MHz, the IFSEL has to be connected to Vcc (current setting of the EVB). For IF2 of 455kHz, the IFSEL has to be connected to GND.

You will find such information in the last version of EVB71120 available on our web-site.

Best Regards
Denis