Dear,
Increasing the resistor R3 of the external detector will reduce the DC level but will also increase the time constant of C3 and R3. This is not be suitable for a correct reception (the the stabilization time may be too big).
Anyhow, it seems that in you application, the RFID reader has to receive a quite large back modulation from the TAG (sub-carrier of about 1V peak). I am afraid that with such a big modulation, the MLX90121 enters in saturation, even if the external an external diode detector is used. The only solution is to use an attenuation cirucit like you did.
Best Regards Denis
|